This site uses cookies so that we can provide you with the best possible user experience. The information in the cookies is stored in your browser and performs functions such as recognizing you when you return to our site or helping our team understand what sections of the site you find most interesting and useful.
Bibliography
Journal of Oral & Maxillofacial Implants; 22; 995-1000; 2007. Canullo L, Rasperini G.
PURPOSE:
The purpose of this article is to evaluate the soft- and hard-tissue response to immediately placed implants. In addition, assessment was conducted of the soft tissue response to a transmucosal abutment which was narrower than the implant platform.
MATERIALS AND METHODS:
This study was conducted to evaluate 10 consecutively placed immediately loaded implants placed in extraction sockets in maxillae without compromised bone tissue. The infection control phase of periodontal therapy was completed in the areas of hopeless teeth prior to extraction. Implants with a 6-mm-platform diameter were placed immediately into the fresh extraction sockets. A provisional 4-mm-diameter transmucosal abutment was subsequently connected, and a provisional crown was adapted and adjusted for nonfunctional immediate positioning. Three months following implant placement, definitive prosthetic rehabilitation was performed. At the time of prosthesis insertion (baseline) and every 6 months thereafter, radiographic assessments, pocket probing depth (PPD), recession, and papilla height were measured. An image analysis software application was used to compare the radiographic bone crestal bone heights at the mesial and distal aspects of the implants.
RESULTS:
Nine patients with 10 sites were treated. Mean follow-up time was 22 months (range, 18 to 36 months). All 10 implants were found to be clinically osseointegrated. Software analysis of radiographic films showed a bone resorption of 0.78 +/- 0.36 mm. The mean values were significantly lower (P < or = .005) than a mean reference value of 1.7 mm. PPD did not exceed 3 mm in any site (average, 2.8 mm). Rather than recession, there was a mean gain in the buccal margin of 0.2 mm and a mean gain in papilla height of 0.25 mm.
CONCLUSION:
This proof-of-concept study suggests that immediate loading with platform switching can provide peri-implant hard tissue stability with soft tissue and papilla preservation. (Case Series).
This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, or the most popular pages.
Leaving this cookie active allows us to improve our website.
Please activate the strictly necessary cookies first so that we can save your preferences!
More information about our cookie policy